6 OPzS 300 Tubular Plate Lead Acid Gel Cell Batteries High Efficiency

Wuhan Changguang Battery Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Wuhan Changguang Battery Co., Ltd
City: Wuhan
Province/State: Hubei
Country/Region: China
Tel: 86-27-84891323
Contact Person:
Mr Song_Gao

6 OPzS 300 Tubular Plate Lead Acid Gel Cell Batteries High Efficiency

Brand Name : CGB
Model Number : 6OPzS300
Certification : CE/UL/ISO
Place of Origin : China
MOQ : 100 pcs
Price : negotiation
Payment Terms : T/T or L/C
Supply Ability : 54000 pcs per month
Delivery Time : 30 days
Packaging Details : Packed in carton, and then reinforced with pallet or wooden case for outer packing
Product Name : 6OPzS300
Application : Electric Utility and equipment
Voltage : 2V
Capacity : 300AH
Size Of Battery : 145*206*354mm
Terminal : M8
Weight : 17 KG
Case : ABS, SAN
Contact Now

6 OPzS 300 Tubular Plate Lead Acid Gel Cell Batteries High Efficiency


Specifications:

Nominal Voltage2V
Nominal Capacity (C20)300Ah (1.80V @ 20℃)
DimensionLength145mm
Width206mm
Height354mm
Total Height409mm
Weight(With Electrolyte)Approx. 22 kg
TerminalM8
Internal ResistanceFull charged@20℃: 0.00075 Ohm
Max Charging Current60A

Description:

● Designed life for floating charge is 20 years according to IEC60896-11;

● Rubber separator with floating electrolyte technology;

● High strength ABS material for cover and SAN material transparent container;

● Wide temperature scope of application (-15~45℃);

● Best temperature of application (20±5℃);

● Special filter installation for acid fog proof;

● Transparent container, convenient to observe;

● Super long service life.


Applications:

● Telecommunications

● Cable Television

● Electric Utility

● Alarm & Security system

● UPS

● Control Equipment

● Medical Equipment

● Railroad Utility

● Photovoltaic System

● Alternative Energy System

● High Power Backup Supply


Maintenance

● Give periodically supplementary charge to the battery for long storage.


● For the circumstances that the battery hasn’t been made supplementary charge according to the requirements after accidental discharge, the batteries can’t be used to supply power further if the power fails again.


● No parallel use of the battery group with different capacities.


● Each setting parameter shouldn’t exceed the regular range of this manual.


Precautions

● Fire hazard

During battery installation, make sure to fix the connecting terminals of the conducting wire tight, and keep the output terminals of the batteries clean. Otherwise, it may lead to a high temperature of battery terminals and even to spark/fire.


● Acid-corrosion danger

No great impact shack and dump-age of the battery when handling and operating. Otherwise, it may cause the leakage of the acid.

on mixing the acid, please wear the protections: face-guard, acid-proof shoes, acid-proof glove, acid-proof clothes & eye-protector.

never have the acid spill on skin, eyes without any protections & also no acid on equipment or floor.


● Operation regulation

Before battery operation, read the safety precaution/instruction, and the operation instructions, especially the battery interconnection instructions.

substandard operation will cause danger. Prevent battery short circuit and prevent battery electrolyte from flowing out. Overflowed electrolyte is a latent danger and it will erode the metal object and circuit board, thus damaging the equipment and causing short circuit of the circuit board.


● The Operation Environment

The battery should be kept far away from fire, organic solution; avoid direct sunshine and the temperature should be the same of the same set.


Tips

● For maximum life expectancy, the R.M.S. ripple current should be regulated to no more than 0.1C (10% of battery's rating).


● Do not crush, incinerate or dismantle the battery. The electrolyte contains sulfuric acid which can cause serious damage to eyes and skin. Should this occur, flush profusely with water and seek medical attention.


● Mixing batteries of different capacities, age and/or manufacture is not recommended. Please consult with an application engineer if it is unavoidably necessary.


● Battery life is dependent on its operating conditions. Please refer to the life curves published in this Applications Manual. These curves represent typical results under optimum operating conditions. Actual life will vary greatly due to variability of these conditions. To obtain optimum battery performance for standby service, CGB recommends that within five years of use, the batteries be replaced.


Product Tags:

flooded lead acid batteries

      

OPzS batteries

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

6 OPzS 300 Tubular Plate Lead Acid Gel Cell Batteries High Efficiency Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Wuhan Changguang Battery Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0